GGD Low voltage fixed switchgear

GGD type AC low-voltage distribution cabinet is applicable to the power distribution system with AC 50Hz, rated working voltage of 380V and rated working current of 3150A for power plants, substations, factories and mining enterprises and other power users. It is used for power conversion, distribution and control of power, lighting and distribution equipment.
华拓集团
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Category
Product
1
Product description
Parameters

Product overview
GGD type AC low-voltage distribution cabinet is applicable to the power distribution system with AC 50Hz, rated working voltage of 380V and rated working current of 3150A for power plants, substations, factories and mining enterprises and other power users. It is used for power conversion, distribution and control of power, lighting and distribution equipment.

 

Model meaning

G

G

D

AC low voltage distribution cabinet Fixed installation and wiring of electrical components Power cabinet Design serial number:
The breaking capacity is 15ka; Breaking capacity is 30ka;
The breaking capacity is 50kA
Main circuit scheme code Auxiliary circuit scheme code

 

Working conditions
◊ the ambient air temperature shall not be higher than + 40 ° C and not lower than - 5 ° C, and the average temperature within 24 hours shall not be higher than + 35 ℃;
◊ for indoor installation and use, the altitude of the place of use shall not exceed 2000m;
◊ the relative humidity of the surrounding air shall not exceed 50% when the maximum temperature is + 40 ° C. It shall be allowed to have a large relative humidity at a lower temperature (for example, 90% at + 20 ° C), taking into account the impact of occasional condensation due to the change of temperature;
◊ when installing the equipment, the inclination with the vertical plane shall not exceed 5.;
◊ the equipment shall be installed in places without violent vibration and impact, as well as places where it is insufficient to cause corrosion of electrical components;
◊ if users have special requirements, they can negotiate with the manufacturer.

 

Technical parameter

Model Rated voltage (V) Rated current (A)

Rated short-circuit breaking current(kA)

Rated short-time withstand current(ls)(kA)

Rated short-time withstand current(kA)

GGD1

380

A

1000

15

15

30

GGD1

380

B

600(630)

15

15

30

GGD1

380

C

400

15

15

30

GGD2

380

A

1500(1600)

30

30

63

GGD2

380

B

1000

30

30

63

GGD2

380

C

600

30

30

63

GGD3

380

A

3150

50

50

105

GGD3

380

B

2500

50

50

105

GGD3

380

C

2000

50

50

105

 

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Message

Username used for comment:
客户留言
Description:
验证码

contact us

Service hotline:400-615-2226

Sales Hotline:0375-3688888/4852222

After-sale service:0375-8952222/2888000

FAX:0375-2555000

WEB:www.huatuodianli.cn

ADD:Huatuo Electric Power Industrial Park, east section of Shenma Avenue, Pingdingshan high tech Zone, Henan Province

华拓电力装备集团有限公司

Copyright ©  2021 Huatuo Power Equipment Group Co., Ltd All rights reserved    豫ICP备15036106号-1

Official website construction:300.CN LUOYANG