SCB14 epoxy resin cast dry-type transformer
SCB14 epoxy resin cast dry-type transformer
+
  • SCB14 epoxy resin cast dry-type transformer
  • SCB14 epoxy resin cast dry-type transformer

SCB14 epoxy resin cast dry-type transformer

SCB14 series epoxy resin cast dry-type transformer, because its coil is encapsulated by epoxy resin, so flame retardant, fire-proof, explosion-proof, maintenance-free, no pollution, small size, can be directly installed in the load center. At the same time, scientific and reasonable design and pouring process make the product less local discharge, low noise, strong heat dissipation capacity, long-term operation under 140% rated load under forced air cooling conditions, and equipped with intelligent temperature controller, with fault alarm, over-temperature alarm, over-temperature trip and black gate functions, and connected to the computer through RS485 serial interface, can be centralized monitoring and control.
Certification

Category:

Telephone:

Product Details


Product Summary

SCB14 series epoxy resin cast dry-type transformer, because its coil is encapsulated by epoxy resin, so flame retardant, fire-proof, explosion-proof, maintenance-free, no pollution, small size, can be directly installed in the load center. At the same time, scientific and reasonable design and pouring process make the product less local discharge, low noise, strong heat dissipation capacity, long-term operation under 140% rated load under forced air cooling conditions, and equipped with intelligent temperature controller, with fault alarm, over-temperature alarm, over-temperature trip and black gate functions, and connected to the computer through RS485 serial interface, can be centralized monitoring and control.

 

Model meaning

S

C

(B)

10

Three-phase transformer

forming solid casting

low voltage foil coil

Design serial number

Rated capacity (kVA)

HV side voltage level (kV)

 

Working conditions

Installation height: altitude not exceeding 1000m;

The waveform of the power supply voltage: similar to a sine wave;

Symmetry of multi-phase power supply voltage: the power supply voltage connected to the multi-phase transformer should be approximately symmetrical;

Ambient temperature: maximum temperature 40°C; The highest daily average temperature is 30°C; The highest annual average temperature is 20°C; The minimum temperature is -30°C (applicable to indoor transformers).

 

Technical parameters

Rated capacity (kVA)

voltage combination

Bonding group

Label

Loss (120 ° kW)

No-load current (%)

Short Circuit Impedance (%)

Weight (kg)

High voltage (kV)

High voltage tap range (%)

LV (kV)

 

No-load

Load

Oil weight

Total weight

30

6

6 3

6.6

10

10.5

11

±5%

± 2 × 2.5%

0.4

Yyn0

Dyn11

130

605

1.6

4

250

320

50

185

845

1.4

370

460

63

250

1160

1.2

460

550

80

270

1330

1.1

490

580

100

320

1565

1.0

570

680

125

365

1800

1.0

640

750

160

420

2135

0.9

775

890

200

490

2330

0.8

895

1030

250

600

2945

0.8

1100

1250

315

665

3375

0.7

1200

1350

400

790

4130

0.7

1460

1610

500

910

4975

0.6

1680

1840

630

885

5050

0.6

6

1800

1980

800

1035

5895

0.5

2130

2310

1000

1205

6885

0.45

2520

2720

1250

1420

8190

0.45

3075

3300

1600

1665

9945

0.45

3670

3900

2000

2075

12240

0.4

4420

4670

2500

2450

14535

0.4

5310

5580

 

Key words:

SCB14 epoxy resin cast dry-type transformer

Get Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit immediately