KYN28-12 armored metal enclosed switchgear (national network standardized customization)
+
  • KYN28-12 armored metal enclosed switchgear (national network standardized customization)

KYN28-12 armored metal enclosed switchgear (national network standardized customization)

KYN28-12 type indoor AC metal armored mid-mounted switchgear. It is suitable for three-phase AC rated voltage 12kV, rated frequency 50Hz power system, used to accept and distribute electrical energy and the circuit control, protection, wireless temperature measurement, online monitoring device.
Certification

Category:

Telephone:

Product Details


Product overview

KYN28-12 type indoor AC metal armored mid-mounted switchgear. It is suitable for three-phase AC rated voltage 12kV, rated frequency 50Hz power system, used to accept and distribute electrical energy and the circuit control, protection, wireless temperature measurement, online monitoring device.

This product meets the requirements of GB3906 "3 ~ 35kV AC Metal Enclosed Switchgear", GB/T11022 "Common Technical Requirements for Standards of High Voltage Switchgear and Control Equipment", IEC60298 "Rated Voltage IkV Above 52kV and Below AC Metal Enclosure Switchgear and Control Equipment", DL/T404 "Technical Conditions for Indoor AC High Voltage Switchgear.

 

Model meaning

K

Y

N

28

12

Mouth

metal enclosed armored type

Move away

(Handcart center type)

Indoor use

Design serial number

Fixed voltage (kV)

Primary circuit scheme

Environmental feature code:

TH-for wet zest TA-for dry zest G-for high altitude; C- for cold zone

 

Working conditions

Ambient air temperature: upper limit 40 C, lower limit -10 C in general area, altitude: 1000m;

Relative humidity: daily average not more than 95%, monthly average not more than 90%;

Water vapor pressure: the daily average is not more than 2.2Kpa, the monthly average is not more than 1.8Kpa;

The product is suitable for the following two environmental conditions that are more severe than normal conditions;

Not frequent condensation (no more than twice a month on average) with mild contamination;

Usually no condensation (no more than twice a year on average) with more serious contamination;

The absence of fire, explosion hazards and harsh areas such as gases that are sufficiently dirty to corrode metals and damage insulation;

There are no places with severe vibration, turbulence and vertical inclination not exceeding 8 °.

 

Technical parameters

Project Unit Parameters
Rated voltage kV 3.6,7.2,12
Rated frequency Hz 50
Rated current of circuit breaker A 630,125,016,002,000,000,000,000,000
Rated current of switch cabinet A 630,125,016,002,000,000,000,000,000
Rated dynamic stability current (4S) kA 16,20,25,31.5,40,50
Rated stable current (peak) kA 40,50,63,80,100,125
Rated short-circuit breaking current kA 16,20,25,31.5,40,50
Rated short-circuit closing current (peak) kA 40,50,63,80,100,125
Rated insulation level Imin power frequency withstand voltage kV 24 32 42
  Lightning impulse withstand voltage kV 40 60 75
Protection level   Enclosure IP4X, isolation room, circuit breaker chamber door open IP2X

 