YB Port -12/0.4(F R) Outdoor Pre-installed Substation (European) (Standardized Customization of State Grid)
+
  • YB Port -12/0.4(F R) Outdoor Pre-installed Substation (European) (Standardized Customization of State Grid)

YB Port -12/0.4(F R) Outdoor Pre-installed Substation (European) (Standardized Customization of State Grid)

YBKou-12/0.4(F · R) outdoor pre-installed substation (European style) is widely used in indoor and outdoor places such as urban power grid reconstruction, residential quarters, high-rise buildings, industrial and mining, hotels, shopping malls, airports, railways, oil fields, docks, expressways and temporary power facilities.
Certification

Category:

Telephone:

Product Details


Product overview

YBKou-12/0.4(F · R) outdoor pre-installed substation (European style) is widely used in indoor and outdoor places such as urban power grid reconstruction, residential quarters, high-rise buildings, industrial and mining, hotels, shopping malls, airports, railways, oil fields, docks, expressways and temporary power facilities.

 

Model meaning

YB

HV/LV prefabricated substation

Arrangement:

M means "eye" and P means "product"

Rated voltage of HV side (KV)

LV side rated voltage (KV)

Rated capacity of transformer (KVA)

 

Working conditions

Altitude: ≤ 1000m;

Ambient temperature: 30 ℃ ~ 40 ℃;

Temperatures: maximum monthly average temperature of 30°C, maximum annual average temperature of 20°C;

Relative humidity: daily average ≤ 95%, monthly average ≤ 90%;

Anti-vibration level: horizontal acceleration 0.4m/s2, vertical acceleration 0.15m/s2;

Installation location: no severe impact, serious pollution and chemical corrosion, no conductive dust and explosion dangerous places.

 

Technical parameters

Name Project Unit Parameters
High voltage unit Rated frequency HZ 50
Rated voltage KV 6 10 35
Maximum operating voltage KV 6.9 11.5 40.5
Rated current A 440、11.5、40.5
transfer current A 1200 a 3150
Power frequency withstand voltage to ground and phase/isolation fracture KV 42/48
Lightning impulse withstand voltage to ground and phase/isolation fracture KV 75/85
Rated short-circuit breaking current (current-limiting fuse) KA 31.5
Transformer Unit Rated voltage KV 6、 10、 35
  Rated capacity KVA 30 a 2000
  tap range % ±2X2.5%、±5%
  Connection group   Yyn0、 Dyn11
  Impedance voltage % 4、4.5、6、8
Low voltage unit Rated voltage IV 220、 380、 690、 800
  Rated current of main circuit IA 50 a 4000
  branch current 1A 5-800
Shell Degree of protection (regular products)   High-voltage chamber IP33; transformer chamber IP23; low-voltage chamber IP33
  Noise level dB ≤50

 

Key words:

YB Port -12/0.4(F R) Outdoor Pre-installed Substation (European) (Standardized Customization of State Grid)

Get Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit immediately