GW□ -12 outdoor high voltage isolating switch
GW□ -12 outdoor high voltage isolating switch
GW□ -12 outdoor high voltage isolating switch
+
  • GW□ -12 outdoor high voltage isolating switch
  • GW□ -12 outdoor high voltage isolating switch
  • GW□ -12 outdoor high voltage isolating switch

GW□ -12 outdoor high voltage isolating switch

GW□ -12 outdoor high voltage isolation switch is suitable for power system with frequency of 50Hz and rated voltage of 12KV. The switch device is on the outdoor high-voltage power distribution equipment line for the line to open and close the circuit when there is voltage and no load. Among them, the pollution flashover problem occurs during the operation of the pollution-proof isolating switch. The switch has three-pole linkage, good contemporariness, and is equipped with an orphan guiding device, equipped with a middle spring, which can realize rapid opening and closing. It has the advantages of breaking and closing small inductance and capacitance current.
Certification

Category:

Telephone:

Product Details


Product overview

GW□ -12 outdoor high voltage isolation switch is suitable for power system with frequency of 50Hz and rated voltage of 12KV. The switch device is on the outdoor high-voltage power distribution equipment line for the line to open and close the circuit when there is voltage and no load. Among them, the pollution flashover problem occurs during the operation of the pollution-proof isolating switch. The switch has three-pole linkage, good contemporariness, and is equipped with an orphan guiding device, equipped with a middle spring, which can realize rapid opening and closing. It has the advantages of breaking and closing small inductance and capacitance current.

 

Model meaning

G

W

12

1250

31.5

Isolating switch

Installation place outdoor

The design serial number is represented by numbers

Rated voltage

Rated current

Rated short-time withstand current

 

Working conditions

The altitude does not exceed 3000m;

ambient air temperature:-30°C ~ 40°C;

The wind pressure does not exceed 700Pa (equivalent to a wind speed of 34 m/s);

The ice thickness is not more than 10mm;

External insulation pollution level: III;

The seismic fortification intensity is 8 degrees;

The installation site shall be subject to the influence of violent vibration and flammable, explosive substances and chemically corrosive gases.

 

Working conditions

Project

Unit

Parameters

Rated voltage

kV

12

Rated current

A

1250

Rated frequency

Hz

50

Rated short-circuit withstand current duration

s

4

Rated short-time withstand current (main circuit)

kA

31.5

Rated peak withstand current (main circuit)

kA

80

Rated short-time power frequency withstand voltage

Dry Test

kV

42

 

Wet Test

kV

34

Rated lightning impulse withstand voltage

Dry Test

kV

75

 

Wet Test

kV

/

Rated short-time power frequency withstand voltage (fracture)

Dry Test

 

kV

 

Wet Test

kV

48

Rated lightning impulse withstand voltage (fracture)

Dry Test

kV

85

 

Wet Test

kV

/

Mechanical life

Times

3000

Loop resistance

 

≤100

 

Key words:

GW□ -12 outdoor high voltage isolating switch

Get Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit immediately