DFW outdoor 0.4kV low voltage cable tap box
+
  • DFW outdoor 0.4kV low voltage cable tap box

DFW outdoor 0.4kV low voltage cable tap box

DFW series 0.4KV low-voltage cable branch box, mainly used in the public power grid, according to the distribution network distribution and user requirements, according to a variety of sub-line mode, box type and installation method, so that users in the flexible scheme easy to choose. In the construction and transformation of the national city network, it is a support product to replace the overhead line. It is widely used in low-voltage power transmission and distribution systems with three-phase AC 380/220V and rated current below 1250A, such as power transformation and distribution stations, industrial and mining enterprises, both sides of streets, garden residential quarters, high-rise buildings, airports, construction and renovation projects, etc., as a complete set of stereotyped equipment for distributing electric energy to other users or equipment with cables.
Certification

Category:

Telephone:

Product Details


Product overview

DFW series 0.4KV low-voltage cable branch box, mainly used in the public power grid, according to the distribution network distribution and user requirements, according to a variety of sub-line mode, box type and installation method, so that users in the flexible scheme easy to choose. In the construction and transformation of the national city network, it is a support product to replace the overhead line. It is widely used in low-voltage power transmission and distribution systems with three-phase AC 380/220V and rated current below 1250A, such as power transformation and distribution stations, industrial and mining enterprises, both sides of streets, garden residential quarters, high-rise buildings, airports, construction and renovation projects, etc., as a complete set of stereotyped equipment for distributing electric energy to other users or equipment with cables.

 

Model meaning

DFW

0.4

□

□

□

 

LV cable branch box

Rated voltage (kV)

Incoming current (A)

Outlet current (A)

Number of incoming lines

Outlet number

 

Working conditions

Altitude: ≤ 2000 m;

High ambient temperature: 45°C, low ambient temperature:-25°C;

Sunshine intensity: 0.1W/cm2 (wind speed: 0.5 m/s), large daily temperature difference: 25K;

Indoor relative humidity: daily average <95%, monthly average <90%;

High wind speed: 35 m/s (Note: wind speed refers to the lOmin average wind speed at a height of 10m from the ground);

Load: 10mm ice cover and 17.5 m/s wind speed at the same time;

Earthquake resistance: ground horizontal acceleration 0.2g; Vertical acceleration O.lg acts simultaneously. The resonance, sine and beat wave test methods shall be adopted; the vibration shall be excited for 5 times, with 5 waves for each time, with an interval of 2s for each time. Safety factor is not less than 1.67;

Rated frequency of the system: 50Hz.

 

Technical parameters

Project Name

Unit

Technical parameters

Rated voltage

kV

0.4

Rated current

A

630

Rated short-time withstand current

kA

20/3

Rated peak withstand current

kA

50

DC withstand voltage (15min)

kV

52

5min power frequency withstand voltage

kV

45

Lightning impulse withstand voltage

kV

105

Partial discharge

PC/kV

<10/15

Loop resistance

μΩ

≤ 4

Protection level

 

IP44

Use ambient temperature

°C

-50 to 60

Applicable cable section

mm2

25-400

 

Key words:

DFW outdoor 0.4kV low voltage cable tap box

Get Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit immediately