ZW32-12 circuit breaker on secondary fusion column
+
  • ZW32-12 circuit breaker on secondary fusion column

ZW32-12 circuit breaker on secondary fusion column

The deep fusion electronic transformer scheme of circuit breaker on the primary and secondary fusion column meets the requirements of the standardized customization scheme of the State Grid. It integrates the industry-preferred electronic voltage transformer and electronic current transformer, cooperates with the electronic automatic feeder terminal, has the functions of remote control, telemetry, remote signaling and fault detection, and communicates with the main station of power distribution automation to provide the operation condition of the power distribution system, various parameters and information required for monitoring and control, including switch status, power parameters, phase-to-phase fault, ground fault and fault parameters, and the implementation of the main distribution station issued by the command, the power distribution equipment to adjust and control, to achieve fault location, fault isolation and non-fault area fast recovery of power supply and other functions.
Certification

Category:

Telephone:

Product Details


Product overview

The deep fusion electronic transformer scheme of circuit breaker on the primary and secondary fusion column meets the requirements of the standardized customization scheme of the State Grid. It integrates the industry-preferred electronic voltage transformer and electronic current transformer, cooperates with the electronic automatic feeder terminal, has the functions of remote control, telemetry, remote signaling and fault detection, and communicates with the main station of power distribution automation to provide the operation condition of the power distribution system, various parameters and information required for monitoring and control, including switch status, power parameters, phase-to-phase fault, ground fault and fault parameters, and the implementation of the main distribution station issued by the command, the power distribution equipment to adjust and control, to achieve fault location, fault isolation and non-fault area fast recovery of power supply and other functions.

 

Working conditions

Altitude: ≤ 2000m and below;

Ambient air temperature: upper limit 30°C, lower limit -40°C; The wind pressure does not exceed 700Pa (equivalent to wind speed 34 m/s);

Amplitude: inconstant violent vibration;

Anti-pollution level III.

 

Technical parameters

Type of transformer

Project

Parameter Value

Electronic and Digital Transformers

Power transformer

Power supply: line voltage 10kV/0.22kV, level 3

 

Voltage transformer

Measurement:(10kW/根号3) / (3.25W/根号3) , 0.5 level

 

 

Zero sequence voltage sensor

(10kV/根号3) / (6.5V/根号3) Class 3P

 

phase current transformer

600A/1V 0.5 class

 

sequence current transformer

20A/0.2A, Grade 1, 10P30

 

Key words:

ZW32-12 circuit breaker on secondary fusion column